Multifunction Substation Tester

• Controllable single‑phase current & voltage source with 5 kVA rated output power.
• Commissioning, periodic, and diagnostic testing for substation assets: power transformers, CTs, VTs/CVTs, circuit breakers, grounding systems, busbars, and more.
• Web‑based software (no installation) with dedicated “test rooms” and wiring diagrams; works via Wi‑Fi/Ethernet and also from the built‑in touchscreen LCD.
• Complementary modules available to extend test capabilities and reduce test time (TEM1, CM1, CB1).
• Suitable for HV and distribution substations, power plants, labs/universities, and industrial sites (refineries/petrochemical).

One Platform for Complete, Advanced Substation Equipment Testing and Diagnostics.

ALLINA T1

All You Need to Test Substation Assets On Site

All-in-One Substation Test Solution.

ALLINA T1 is a controllable single‑phase current and voltage source designed to bring a wide range of commissioning, periodic, and diagnostic tests directly to the field. It supports transformer, CT/VT/CVT, circuit breaker, grounding, and line/cable related measurements, and it can be expanded with complementary modules to fit specialized applications and minimize overall test time.

Power Transformers

Current Transformers

Voltage Transformers

Circuit Breakers

Grounding System, Overhead Line, and Cable

Protection Systems

What are the key features of ALLINA T1?

Quick Mode

Selectable AC/DC voltage and current outputs and inputs with configurable limits and trigger modes.

Sequencer Mode

Employing up to 10 sequences with different amplitude and test time

High-power primary injection

5 kVA high‑power primary injection for comprehensive on‑site commissioning and diagnostic testing.

Controllable AC/DC voltage & current outputs

Up to 2200V AC, 260V DC, 1000A AC, and 400A DC with selectable channels

Web-based, device-independent interface

Built-in web server allows control from laptops, tablets, or smartphones without installing software, enabling flexible use in labs and in the field.

AC/DC operation with variable frequency

Supports AC and DC tests with adjustable frequency from 15–120 Hz, allowing you to study behavior at nominal and off‑nominal conditions using the same platform.
Read More
Image description

Guided wiring diagrams in every test room

Software “test rooms” display live wiring diagrams for each test, helping users connect outputs, inputs, and grounds correctly, reduce connection errors, and safely start injection with clear visual guidance.
Read More
Image description

Structured results with tables and graphs

ALLINA T1 software organizes test results into clear tables and graphical plots, making it easy to inspect key values, compare different steps or sequences, and quickly identify trends or anomalies for analysis and reporting
Read More
Image description

Online web‑based software access for report analysis

With ALLINA T1 you can access saved test projects directly in your web browser. Review tables & charts, compare performance between assets, and generate reports from whatever device you’re using — no special software needed.
Read More
Image description
Multifunction source for fast substation commissioning and diagnostics

5 kVA

Rated single‑phase power

15–120 Hz

Variable AC test frequency range

2200 V / 1000 A AC

Maximum AC output voltage/Current

260 V / 400 A DC

Maximum DC output voltage/Current

ALLINA T1 features web-based software that eliminates the need for installation and runs seamlessly on computers, tablets, and smartphones. Specific test rooms provide corresponding wiring diagrams tailored to test parameters, while the user-friendly interface supports both Wi-Fi and Ethernet connections. The built-in touchscreen LCD delivers the same performance as connected devices, with aided guidance through all test steps that automatically generates results. An online project management website and manageable database complete the ecosystem for efficient data handling.

ALLINA T1 in Action

See how ALLINA T1 transforms on-site substation testing. From guided wiring diagrams and sequencer workflows to high-power primary injection and instant results, these videos showcase how engineers perform accurate commissioning and diagnostics with confidence—anywhere, anytime.​

Our experts are ready to answer all your questions.

You can ask your questions in various ways on this site. Our communication methods are through social networks, email, or phone calls. So you can contact us in various ways. Our experts are ready to answer you.

ALLINA T1 handles commissioning, periodic, and diagnostic tests on power transformers, CTs, VTs/CVTs, circuit breakers, grounding systems, busbars, and transmission lines/cables using primary injection and high-voltage sourcing.

No—its web-based software runs directly in any browser on computers, tablets, or smartphones via WiFi/Ethernet, with full touchscreen operation on the device itself.

TEM1, CM1, and CB1 modules attach directly to the main unit for single-wiring setups, enabling 3-phase transformer tests, line/grounding measurements, and breaker timing with reduced setup time.

High-voltage/distribution substations, power plants, research labs, universities, and industrial sites like refineries—rugged for field use with 10–55°C operation and dual-ground safety.

You can use the following methods to Contact Us

You can reach Wisegrid Energy through the following channels. Our team is ready to support you with technical inquiries, product information, and partnership opportunities.

Article Post
//
Our customer support team is here to answer your questions. Ask us anything!
👋 Hi, how can I help?